Undecylenic Acid
If you find any inaccurate information, please let us know by providing your feedback here

This article is compiled based on the United States Pharmacopeia (USP) – 2025 Edition
Issued and maintained by the United States Pharmacopeial Convention (USP)
C11H20O2 184.28
10-Undecenoic acid;
Undec-10-enoic acid CAS RN: 112-38-9; UNII: K3D86KJ24N.
Change to read:
1 DEFINITION
Undecylenic Acid contains NLT 97.0% and NMT102.0% (USP 1-Aug-2022) of undecylenic acid (C11H20O2).
2 IDENTIFICATION
Delete the following:
Sample: 1 mL of Undecylenic Acid
Analysis: To the Sample add potassium permanganate TS dropwise.
Acceptance criteria: The permanganate color is discharged. (USP 1-Aug-2022)
Add the following:
A. SPECTROSCOPIC IDENTIFICATION TESTS (197), Infrared Spectroscopy: 197A or 197F (USP 1-Aug-2022)
Change to read:
B. The retention time of the undecylenic acid peak of the Sample solution corresponds to that of the Standard solution, as obtained in the Assay (USP 1-Aug-2022)
3 ASSAY
Change to read:
PROCEDURE
Undecyle Standard solution: 0.5 mg/mL of USP Undecylenic Acid RS in n-heptane
Sample solution: 0.5 mg/mL of Undecylenic Acid in n-heptane
Chromatographic system
(See Chromatography (621), System Suitability.)
Mode: GC
Detector: Flame ionization
Column: 0.25-mm × 30-m fused-silica capillary; coated with a 0.25-μm lm of phase G35
Temperatures
Injection port: 280°
Detector: 350*
Column: See Table 1.
Table 1
| Initial Temperature (°) | Temperature Ramp (°/min) | Final Temperature (°) | Hold Time at Final Temperature (min) |
| 100 | - | 100 | 5 |
| 100 | 10 | 220 | 13 |
| 220 | 30 | 240 | 15 |
Carrier gas: Helium
Flow rate: 0.7 mL/min
Injection volume: 1 μL
Injection type: Split, split ratio 25:1
System suitability
Sample: Standard solution
Suitability requirements
Tailing factor: NMT 2.0
Relative standard deviation: NMT 1.0%
Analysis
Samples: Standard solution and Sample solution
Calculate the percentage of undecylenic acid (C11H20O2) in the portion of Undecylenic Acid taken:
Result = (ru /rs ) × (Cs /Cu ) × 100
ru = peak response of undecylenic acid from the Sample solution
rs = peak response of undecylenic acid from the Standard solution
Cs = concentration of USP Undecylenic Acid RS in the Standard solution (mg/mL)
Cu = concentration of Undecylenic Acid in the Sample solution (mg/mL) (USP 1-Aug-2022)
Acceptance criteria: 97.0%–102.0% (USP 1-Aug-2022)
4 IMPURITIES
Residue on Ignition 〈281〉: NMT 0.15%
Water-Soluble Acids
Sample: 5 mL of Undecylenic Acid
Titrimetric system
Mode: Direct titration
Titrant: 0.01 N sodium hydroxide VS
Endpoint detection: Visual
Analysis: Shake the Sample with 5 mL of water and lter the water layer through a lter paper previously moistened with water. Add 1 drop of
methyl orange TS, and titrate with Titrant.
Acceptance criteria: NMT 1.0 mL of Titrant is required to match the color produced by 1 drop of methyl orange TS in 5 mL of water.
5 SPECIFIC TESTS
Specific Gravity 〈841〉: 0.910–0.913
Delete the following:
Congealing Temperature 〈651〉: NLT 21° (USP 1-Aug-2022)
Delete the following:
Refractive Index 〈831〉: 1.447–1.448 (USP 1-Aug-2022)
Fats and Fixed Oils 〈401〉, Procedures, Iodine Value: 131–138
6 ADDITIONAL REQUIREMENTS
Packaging and Storage: Preserve in tight, light-resistant containers.
Add the following:
USP Reference Standards 〈11〉
USP Undecylenic Acid RS (USP 1-Aug-2022)