Synthetic Paraffin

If you find any inaccurate information, please let us know by providing your feedback here

Synthetic Paraffin

Ước tính: 0 phút đọc, Ngày đăng:

This article is compiled based on the United States Pharmacopeia (USP) – 2025 Edition

Issued and maintained by the United States Pharmacopeial Convention (USP)

DOWNLOAD PDF HERE

1 DEFINITION

Synthetic Paraffin is synthesized by the Fischer-Tropsch process from carbon monoxide and hydrogen, which are catalytically converted to a mixture of paraffin hydrocarbons; the lower molecular weight fractions are removed by distillation, and the residue is hydrogenated and further treated by percolation through activated charcoal. This mixture may be fractionated into its components by a solvent separation method, using a suitable synthetic isoparaffinic petroleum hydrocarbon solvent. It may contain NMT 0.005% of a suitable antioxidant.

2 IDENTIFICATION

Change to read:

A. Spectroscopic Identification Tests 〈197〉, Infrared Spectroscopy: 197F. A thin ffilm of it, cast from a melt onto a cesium bromide plate, exhibits a pair of very strong IR absorption peaks between 2840 cm⁻¹ and 3000 cm⁻¹, a pair of moderately strong peaks between 1430 cm⁻¹ and 1490 cm⁻¹, a pair of medium peaks between 720 cm⁻¹ and 750 cm⁻¹, and only weak peaks at any other wavenumbers.

3 IMPURITIES

3.1 Limit of Oil Content

Analysis: Follow ASTM Method D721-68, “Standard Test Method for Oil Content of Petroleum Waxes” (Reapproved 1987).¹

Acceptance criteria: NMT 0.5%

4 SPECIFIC TESTS

4.1 Absorptivity

Sample solution: Transfer 50–100 mg to a 100-mL volumetric ffiask. Dissolve in decahydronaphthalene at 88°, dilute with the same solvent at this temperature to volume, and mix.

Blank: Decahydronaphthalene

Instrumental conditions

  • (See Ultraviolet-Visible Spectroscopy 〈857〉.)
  • Mode: UV
  • Analytical wavelength: 290 nm
  • Cell: 10 cm (jacketed cells maintained at 88°)

Analysis

Samples: Sample solution and Blank

Determine the absorbance of the Sample solution, and calculate the absorptivity.

Acceptance criteria: NMT 0.01

5 ADDITIONAL REQUIREMENTS

Packaging and Storage: Preserve in well-closed containers.

Labeling: The labeling indicates its congealing temperature, viscosity, and needle penetration range under the speciffied conditions.

¹ Available from the American Society for Testing and Materials, 1916 Race St., Philadelphia, PA 19103.

vui lòng chờ tin đang tải lên

Vui lòng đợi xử lý......

0 SẢN PHẨM
ĐANG MUA
hotline
0927.42.6789