1 DEFINITION
Sodium Phenylbutyrate contains NLT 99.0% and NMT 101.0% of sodium phenylbutyrate (C10H11NaO2), calculated on the anhydrous basis.
2 IDENTIFICATION
Change to read:
A. Spectroscopic Identification Tests 〈197〉, Infrared Spectroscopy: 197K (CN 1-May-2020)
B. Identification Tests—General 〈191〉, Sodium
Sample solution: Dissolve 150 mg in 2 mL of water.
Acceptance criteria: Meets the requirements of test A
3 ASSAY
Procedure
Sample: 150 mg
Analysis: Disperse the Sample in 50 mL of anhydrous acetic acid. [Note—The opalescence of the solution disappears during the titration.]
Titrate with 0.1 N perchloric acid VS, determining the endpoint potentiometrically. Each mL of 0.1 N perchloric acid is equivalent to 18.62 mg of sodium phenylbutyrate (C10H11NaO2).
Acceptance criteria: 99.0%–101.0% on the anhydrous basis
4 IMPURITIES
Limit of Phenylbutyrate Related Compound C
Silylation solution: To 2 mL of bis(trimethylsilyl)trifluoroacetamide add 0.04 mL of chlorotrimethylsilane, and mix.
Sample solution: Dissolve 50.0 mg of Sodium Phenylbutyrate in 3 mL of water, and add 0.5 mL of hydrochloric acid. Extract with 2 quantities, each of 5 mL, of methylene chloride. Evaporate the combined methylene chloride extracts to dryness in a vial with a screw cap, and add 0.5 mL of the Silylation solution. Seal the vial, and heat at 70 ± 5° for 20 min.
Standard stock solution: 0.5 mg/mL of USP Phenylbutyrate Related Compound C RS in methylene chloride
Diluted standard stock solution: 0.05 mg/mL of USP Phenylbutyrate Related Compound C RS in methylene chloride from Standard stock solution
Standard solution: Place an amount of the Diluted standard stock solution, equivalent to 0.05 mg, in a vial with a screw cap, evaporate to dryness, and add 0.5 mL of the Silylation solution. Seal the vial, and heat at 70 ± 5° for 20 min.
System suitability solution: Prepare a solution containing 0.4 mg/mL of USP Sodium Phenylbutyrate RS in water. To 3 mL of this solution add 0.1 mL of hydrochloric acid. Extract with 2 quantities, each of 5 mL, of methylene chloride. Combine the methylene chloride extracts in a vial with a screw cap, and add 2 mL of Standard stock solution. Evaporate to dryness, and add 0.5 mL of the Silylation solution. Seal the vial, and heat at 70 ± 5° for 20 min.
Chromatographic system
(See Chromatography 〈621〉, System Suitability.)
Mode: GC
Detector: Flame ionization
Column: 25-m × 0.25-mm fused silica capillary; coated with a 1.0-μm
lm of phase G27
Temperatures
Injector: 270°
Detector: 270°
Column: See Table 1.
Table 1
| Initial Temperature (°) | Temperature Ramp (°/min) | Final Temperature (°) | Hold Time at Final Temperature (min) |
|---|---|---|---|
| 50 | 0 | 50 | 5 |
| 50 | 10 | 270 | 5 |
Carrier gas: Helium
Flow rate: 0.9 mL/min
Injection volume: 1 μL
Split ratio: 1:100
System suitability
Sample: System suitability solution
[Note—The relative retention times for phenylbutyrate related compound C and phenylbutyrate are about 0.98 and 1.0, respectively.]
Suitability requirements
Resolution: NLT 3.0 between the phenylbutyrate related compound C and phenylbutyrate peaks
Analysis
Samples: Standard solution and Sample solution
Calculate the percentage of phenylbutyrate related compound C in the portion of Sodium Phenylbutyrate taken:
Result = (rU/rS) × (WS/WU ) × 100
rU = peak response of phenylbutyrate related compound C from the Sample solution
rS = peak response of phenylbutyrate related compound C from the Standard solution
WS = amount of USP Phenylbutyrate Related Compound C RS taken to prepare the Standard solution (mg)
WU = amount of Sodium Phenylbutyrate taken to prepare the Sample solution (mg)
Acceptance criteria: NMT 0.1%
Organic Impurities
Mobile phase: Methanol, glacial acetic acid, and water (49:1:50)
Impurity stock solution A: 0.1 mg/mL of USP Phenylbutyrate Related Compound A RS in methanol
Impurity standard solution A: Dilute 1.0 mL of Impurity stock solution A with water to 50.0 mL. This solution contains 2 μg/mL of USP Phenylbutyrate Related Compound A RS.
Impurity stock solution B: 0.02 mg/mL of USP Phenylbutyrate Related Compound B RS in methanol
Impurity standard solution B: Dilute 1.0 mL of Impurity stock solution B with water to 50.0 mL. This solution contains 0.4 μg/mL of USP
Phenylbutyrate Related Compound B RS.
System suitability solution: Prepare a solution containing 20 mg/mL of USP Sodium Phenylbutyrate RS in methanol. Transfer 10 mL of this solution to a 50-mL volumetric flask, add 1.0 mL of Impurity stock solution B, and dilute with water to volume.
Sensitivity solution: Dilute 6.0 mL of Impurity standard solution A with water to 10.0 mL. This solution contains 1.2 μg/mL of USP
Phenylbutyrate Related Compound A RS.
Sample solution: 4.0 mg/mL of Sodium Phenylbutyrate, prepared as follows. Dissolve it first in methanol, using 20% of the final volume, and dilute with water to volume.
Chromatographic system
(See Chromatography 〈621〉, System Suitability.)
Mode: LC
Detector: UV 245 nm
Column: 4.6-mm × 25-cm; 5-μm base-deactivated end-capped packing L1
Flow rate: 1.3 mL/min
Injection volume: 20 μL
System suitability
Samples: System suitability solution and Sensitivity solution
Suitability requirements
Resolution: NLT 6 between phenylbutyrate and phenylbutyrate related compound B, System suitability solution
Signal-to-noise ratio: NLT 10, Sensitivity solution
Analysis
Samples: Impurity standard solution A, Impurity standard solution B, and Sample solution
Calculate the percentage of phenylbutyrate related compound A or phenylbutyrate related compound B in the portion of Sodium
Phenylbutyrate taken:
Result = (rU/rS ) × (CS /CU ) × 100
rU = peak response of respective impurity in the Sample solution
rS = peak response of phenylbutyrate related compound A or phenylbutyrate related compound B in the respective Impurity standard solution
CS = concentration of USP Phenylbutyrate Related Compound A RS or USP Phenylbutyrate Related Compound B RS in the respective Impurity standard solution (mg/mL)
CU = concentration of Sodium Phenylbutyrate in the Sample solution (mg/mL)
Calculate the percentage of any individual unspecified impurity in the portion of Sodium Phenylbutyrate taken:
Result = (rU /rS ) × (CS /CU ) × 100
rU = peak response of each unspecified impurity in the Sample solution
rS = peak response of phenylbutyrate related compound A in Impurity standard solution A
CS = concentration of USP Phenylbutyrate Related Compound A RS in Impurity standard solution A (mg/mL)
CU = concentration of Sodium Phenylbutyrate in the Sample solution (mg/mL)
Acceptance criteria: See Table 2. Disregard any peak below 0.03%.
Table 2
| Name | Relative Retention Time | Acceptance Criteria, NMT (%) |
|---|---|---|
| Phenylbutyrate related compound A | 0.3 | 0.1 |
| Phenylbutyrate related compound B | 0.7 | 0.01 |
| Sodium phenylbutyrate | 1.0 | – |
| Any individual unspecified Impurity | – | 0.05 |
| Total impurities | – | 0.1 |
5 SPECIFIC TESTS
Water Determination, Method Ia〈921〉: NMT 0.5%
pH 〈791〉
Sample solution: 20 mg/mL in carbon dioxide-free water
Acceptance criteria: 6.5–7.5
6 ADDITIONAL REQUIREMENTS
Packaging and Storage: Preserve under argon in tight containers. Store at room temperature.
USP Reference Standards 〈11〉
USP Sodium Phenylbutyrate RS
USP Phenylbutyrate Related Compound A RS
3-Benzoylpropionic acid;
4-Oxo-4-phenylbutanoic acid.
C10H10O3 178.18
USP Phenylbutyrate Related Compound B RS
α-Tetralone;
3,4-Dihydronaphthalen-1(2H)-one.
C10H10O 146.19
USP Phenylbutyrate Related Compound C RS
4-Cyclohexylbutanoic acid.
C10H18O2 170.25