Sodium Chloride Inhalation Solution
If you find any inaccurate information, please let us know by providing your feedback here

Tóm tắt nội dung
This article is compiled based on the United States Pharmacopeia (USP) – 2025 Edition
Issued and maintained by the United States Pharmacopeial Convention (USP)
DOWNLOAD PDF HERE
1 DEFINITION
Sodium Chloride Inhalation Solution is a sterile solution of Sodium Chloride in water purified by distillation or by reverse osmosis and rendered sterile. It contains NLT 90.0% and NMT 110.0% of the labeled amount of sodium chloride (NaCl). It contains no antimicrobial agents or other added substances.
2 IDENTIFICATION
A. Identification Tests—General 〈191〉, Chemical Identification Tests, Sodium: Meets the requirements
Delete the following:
B. Identification Tests—General 〈191〉, Chemical Identification Tests, Chloride: Meets the requirements (USP 1-Aug-2021)
Add the following:
B. The retention time of the chloride peak of the Sample solution corresponds to that of the Standard solution, as obtained in the Assay.
(USP 1-Aug-2021)
3 ASSAY
Change to read:
Procedure
Use water with a resistivity of NLT 18 megohm-cm to prepare the solutions.
Solution A: 100 mM potassium hydroxide
Solution B: Water
Mobile phase: See Table 1. [Note—Alternatively, Mobile phase can be generated electrolytically using an automatic eluant generator.]
Table 1
Time (min) | Solution A (%) | Solution B (%) |
| 0 | 5 | 95 |
| 12 | 70 | 30 |
| 15 | 5 | 95 |
| 24 | 5 | 95 |
System suitability solution: 100 μg/mL of USP Sodium Chloride RS and 8 μg/mL of USP Sodium Nitrite RS in water
Standard solution: 100 μg/mL of USP Sodium Chloride RS in water
Sample solution: Nominally 100 μg/mL of sodium chloride from a suitable volume of Inhalation Solution in water
Chromatographic system
(See Chromatography 〈621〉, System Suitability.)
Mode: LC
Detector: Conductivity with suppression
Columns
Guard: 4.0-mm × 5-cm; 11-μm packing L121. [Note—Alternatively, a 4.0-mm × 0.5-cm column that contains 5.0-μm packing L91 may be used.]
Analytical: 4.0-mm × 25-cm; 7.5-μm packing L103. [Note—Alternatively, a 4.0-mm × 15-cm column that contains 5.0-μm packing L91 may be used.]
Column temperature: 35°
Flow rate: 1.2 mL/min
Injection volume: 10 μL
System suitability
Samples: System suitability solution and Standard solution
[Note—The relative retention times for the chloride and nitrite peaks are 1.0 and 1.1, respectively.]
Suitability requirements
Resolution: NLT 2.0 between the chloride and nitrite peaks, System suitability solution
Tailing factor: NMT 2.0 for the chloride and nitrite peaks, System suitability solution
Relative standard deviation: NMT 2.0%, Standard solution
Analysis
Samples: Standard solution and Sample solution
Calculate the percentage of the labeled amount of sodium chloride (NaCl) in the portion of Inhalation Solution taken:
Result = (rU/rS) × (CS/CU) × 100
rU = peak response of chloride from the Sample solution
rS = peak response of chloride from the Standard solution
CS = concentration of USP Sodium Chloride RS in the Standard solution (μg/mL)
CU = nominal concentration of sodium chloride in the Sample solution (μg/mL)
(USP 1-Aug-2021)
Acceptance criteria: 90.0%–110.0%
4 PERFORMANCE TESTS
Add the following:
Uniformity of Dosage Units 〈905〉: Meets the requirements (USP 1-Aug-2021)
5 SPECIFIC TESTS
Sterility Tests 〈71〉: Meets the requirements
pH 〈791〉: 4.5–7.0
6 ADDITIONAL REQUIREMENTS
Change to read:
Packaging and Storage: Preserve in single-dose containers, and store at controlled room temperature. (USP 1-Aug-2021)
Add the following:
USP Reference Standards 〈11〉
USP Sodium Chloride RS
USP Sodium Nitrite RS (USP 1-Aug-2021)