Rocuronium Bromide
If you find any inaccurate information, please let us know by providing your feedback here

This article is compiled based on the United States Pharmacopeia (USP) – 2025 Edition
Issued and maintained by the United States Pharmacopeial Convention (USP)
1 DEFINITION
Rocuronium Bromide contains NLT 98.0% and NMT 102.0% of rocuronium bromide (C₃₂H₅₃BrN₂O₄), calculated on the anhydrous and 2-propanol-free or acetic-acid-free basis.
2 IDENTIFICATION
A. Spectroscopic Identification Tests 〈197〉, Infrared Spectroscopy: 197M
B. The retention time of the rocuronium bromide peak of the Sample solution corresponds to that of the Standard solution, as obtained in the Assay.
C. Identification Tests—General 〈191〉, Bromide
Sample solution: 10 mg/mL
Acceptance criteria: Meets the requirements of test B
3 ASSAY
Procedure
Diluent: Acetonitrile and water (90:10)
Buffer: 4.53 g/L of tetramethylammonium hydroxide pentahydrate. Adjust with phosphoric acid to pH 7.4.
Mobile phase: Acetonitrile and Buffer (90:10)
Standard solution: 1 mg/mL of USP Rocuronium Bromide RS in Diluent
Sample solution: 1 mg/mL of Rocuronium Bromide in Diluent
Chromatographic system
Mode: LC
Detector: UV 210 nm
Column: 4.6-mm × 25-cm; 5-µm packing L3
Column temperature: 30°
Flow rate: 2 mL/min
Injection volume: 5 µL
System suitability
[Note—The system may need equilibration for 4 h.]
Sample: Standard solution
Tailing factor: NMT 2.0
Relative standard deviation: NMT 2.0%
Analysis
Samples: Standard solution and Sample solution
Result = (rᵤ / rₛ) × (Cₛ / Cᵤ) × 100
rᵤ = peak response from the Sample solution
rₛ = peak response from the Standard solution
Cₛ = concentration of USP RS (mg/mL)
Cᵤ = concentration of sample (mg/mL)
Acceptance criteria: 98.0%–102.0%
4 IMPURITIES
Residue on Ignition 〈281〉
NMT 0.1%
Organic Impurities
Diluent, Mobile phase, and Chromatographic system: As directed in Assay.
Peak identification solution: 1 mg/mL of USP Rocuronium Peak Identification Mixture RS in Diluent
Standard solution: 0.01 mg/mL USP Rocuronium Bromide RS
Sample solution: 10 mg/mL Rocuronium Bromide in Diluent
Run time: 2.5 × retention time of rocuronium
System suitability
[Note—System may require 4 h equilibration.]
Peak-to-valley ratio: ≥ 1.5
Resolution: ≥ 3.5 between rocuronium and compound C
Analysis
Result = (rᵤ / rₛ) × (Cₛ / Cᵤ) × (1/F) × 100
Acceptance criteria: Table 1
[Note—Disregard peaks before compound A, and peaks < 0.5 the principal standard peak.]
| Name | Relative Retention Time | Relative Response Factor | Acceptance Criteria NMT (%) |
|---|---|---|---|
| Rocuronium related compound Aᵃ | 0.20 | 2.1 | 0.2 |
| Rocuronium related compound Gᵇ | 0.44 | 2.3 | 0.1 |
| Rocuronium related compound Fᶜ | 0.75 | 0.79 | 0.1 |
| Rocuronium related compound Bᵈ | 0.80 | 1.0 | 0.3 |
| Rocuronium related compound Dᵉ | 0.90 | 1.0 | 0.1 |
| Rocuronium related compound Hᶠ | 0.95 | 2.9 | 0.1 |
| Rocuronium bromide | 1.0 | — | — |
| Rocuronium related compound Cᵍ | 1.20 | 1.0 | 0.3 |
| Rocuronium related compound Eʰ | 1.53 | 1.0 | 0.1 |
| Any individual unspecified impurity | — | — | 0.10 |
| Total impurities | — | — | 1.5 |
a 3α-Hydroxy-2β-(morpholin-4-yl)-16β-(pyrrolidin-1-yl)-5α-androstan-17β-yl acetate.
▲b 2β-(Morpholin-4-yl)-16β-(pyrrolidin-1-yl)-5α-androstane-3α,17β-diol.▲ (ERR 1-Dec-2022)
c 1-[3α,17β-Bis(acetyloxy)-2β-(pyrrolidin-1-yl)-5α-androstan-16β-yl]-1-(prop-2-enyl)pyrrolidinium.
d 1-[3α,17β-Bis(acetyloxy)-2β-(morpholin-4-yl)-5α-androstan-16β-yl]-1-(prop-2-enyl)pyrrolidinium.
e 1-[3α-(Acetyloxy)-17β-hydroxy-2β-(morpholin-4-yl)-5α-androstan-16β-yl]-1-(prop-2-enyl)pyrrolidinium.
f 1-[17β-(Acetyloxy)-2-(morpholin-4-yl)-3-oxo-5α-androst-1-en-16β-yl]-1-(prop-2-enyl)pyrrolidinium.
g 1-[3α,17β-Dihydroxy-2β-(morpholin-4-yl)-5α-androstan-16β-yl]-1-(prop-2-enyl)pyrrolidinium.
h 1-[17β-(Acetyloxy)-3α-hydroxy-2β-(pyrrolidin-1-yl)-5α-androstan-16β-yl]-1-(prop-2-enyl)pyrrolidinium.
Limit of 2-Propanol
[Note—Perform only if 2-propanol is a known process impurity.]
Standard stock solution
Transfer 35.0 µL ethyl ether, 32.0 µL 2-propanol, 19.0 µL methylene chloride to a 100-mL volumetric flask with 90 mL DMF, dilute to volume.
Standard solution
2.5 mL of stock → 25-mL flask with 20 mL DMF → dilute to volume.
Dilute standard solution
1.0 mL of Standard solution + 4.0 mL water in 20-mL headspace vial. Cap and mix.
Sample solution
50 mg Rocuronium Bromide + 1.0 mL DMF + 4.0 mL water in 20-mL vial. Cap and mix.
Chromatographic system (GC)
Mode: GC
Detector: Flame ionization
Column: 0.32-mm × 60-m fused silica coated with 1.8-µm G43
Temperatures
| Initial Temp (°) | Ramp (°/min) | Final Temp (°) | Hold (min) |
|---|---|---|---|
| 50 | 0 | 50 | 8 |
| 50 | 20 | 250 | 8 |
Carrier gas: Helium 55 cm/s or nitrogen 25 cm/s
Injection type: Split 1:6
Headspace autosampler
Sample equilibration temperature: 90°
Equilibration time: 15 min
Transfer line: 140°
System suitability
[Note—Relative retention times: ethyl ether 0.87, 2-propanol 1.0, methylene chloride 1.08]
Resolution: NLT 1.0 between ether & 2-propanol; and between 2-propanol & methylene chloride
RSD: NMT 10% (2-propanol)
Analysis
Result = [(rᵤ / rₛ) × (V × D / W) × 100] / F
rᵤ = Sample 2-propanol peak
rₛ = Standard 2-propanol peak
V = 2-propanol volume used in stock
D = 0.786 mg/µL
W = sample weight
F = 1000
Acceptance criteria: NMT 1.0%
Limit of Acetic Acid
Mobile phase: 6.1 g sodium perchlorate in 800 mL water, adjust pH 2.0 with 1 N sulfuric acid, dilute to 1 L.
Standard solution: 0.2 mg/mL glacial acetic acid
Sample solution: 6 mg/mL Rocuronium Bromide (sonication may be needed)
Chromatographic system (LC)
Detector: UV 205 nm
Column: 4.6-mm × 15-cm; packing L1
Column temperature: 30°
Flow rate: 1 mL/min
Injection volume: 20 µL
System suitability
[Note—Acetic acid retention ≈ 3.8 min]
Column efficiency: NLT 5000 plates
Tailing factor: NMT 1.8
RSD: NMT 5.0% (three injections)
Analysis
Result = (rᵤ / rₛ) × (Cₛ / Cᵤ) × 100
Acceptance criteria: NMT 5.0%
5 SPECIFIC TESTS
Water Determination 〈921〉 Method Ic: NMT 4.0%
pH 〈791〉
Sample: 10 mg/mL
Acceptance: 7.0–9.5
Specific Rotation 〈781S〉
Sample: 10 mg/mL in 0.05 M HCl
Acceptance: 28.5°–32.0° (anhydrous, solvent-free, at 20°)
Color and Achromicity 〈631〉
Reference: 33 mL Matching Fluid G + 67 mL water
Sample: 10 mg/mL in water
Acceptance: Sample not more intensely colored.
6 ADDITIONAL REQUIREMENTS
Packaging and Storage: Tight containers, protect from light/moisture. Store in freezer. If containing acetic acid, store at 2°–8°.
USP Reference Standards 〈11〉
USP Rocuronium Bromide RS
USP Rocuronium Peak Identification Mixture RS
Mixture of approximately 0.2% to 0.4% each of rocuronium related compound A, rocuronium related compound B, rocuronium related compound C, rocuronium related compound D, rocuronium related compound E, rocuronium related compound F, rocuronium related compound G, and rocuronium related compound H in a matrix of rocuronium bromide.