Benzeneacetic acid, α-cyclohexyl-α-hydroxy-, 4-(diethyl amino)-2-butynyl ester hydrochloride, (±)-; 4-(Diethylamino)-2-butynyl (±)-α-phenylcyclohexaneglycolate hydrochloride CAS RN®: 1508-65-2; UNII: L9F3D9RENQ.

1 DEFINITION

Oxybutynin Chloride contains NLT 97.0% and NMT 102.0% of oxybutynin chloride (C21H31NO3 · HCl), calculated on the dried basis.

2 IDENTIFICATION

Change to read:

A. Spectroscopic Identification Tests 〈197〉, Infrared Spectroscopy: 197K (CN 1-May-2020)

B. The retention time of the major peak of the Sample solution corresponds to that of the Standard solution, as obtained in the Assay.

3 ASSAY

Procedure

Buffer: A solution containing 6.67 g/L of monobasic potassium phosphate and 8.55 g/L of dibasic potassium phosphate Mobile phase: Acetonitrile and Buffer (49:51)

Standard solution: 0.1 mg/mL of USP Oxybutynin Chloride RS in Mobile phase

Sample solution: 0.1 mg/mL of Oxybutynin Chloride in Mobile phase

3.1 Chromatographic system

(See Chromatography 〈621〉, System Suitability.)

Mode: LC

Detector: UV 210 nm

Column: 4.6-mm × 7.5-cm; 3-µm or 3.5-µm packing L7

Column temperature: 45°

Flow rate: 1 mL/min

Injection volume: 10 µL

3.2 System suitability

Sample: Standard solution

Suitability requirements

Relative standard deviation: NMT 1.0%

3.3 Analysis

Samples: Standard solution and Sample solution

Calculate the percentage of oxybutynin chloride (C21H31NO3 · HCl) in the portion of Oxybutynin Chloride taken: 

Result = (rU /rS) × (CS /CU ) × 100

rU = peak response from the Sample solution

rS = peak response from the Standard solution

CS = concentration of USP Oxybutynin Chloride RS in the Standard solution (mg/mL)

CU = concentration of Oxybutynin Chloride in the Sample solution (mg/mL)

Acceptance criteria: 97.0%–102.0% on the dried basis

4 OTHER COMPONENTS

Chloride Content

Sample: 600 mg of Oxybutynin Chloride, previously dried

Analysis: Dissolve the Sample in 100 mL of water, and add 5 mL of nitric acid. Titrate (see Titrimetry 〈541〉) with 0.1 N silver nitrate VS, using a platinum–silver chloride electrode system. Each mL of 0.1 N silver nitrate is equivalent to 3.545 mg of chloride (Cl). Acceptance criteria: 8%–10%

5 IMPURITIES

Residue on Ignition 〈281〉: NMT 0.1%

Organic Impurities

Buffer, Mobile phase, and Chromatographic system: Proceed as directed in the Assay.

System suitability stock solution: 100 µg/mL each of USP Oxybutynin Related Compound B RS and USP Oxybutynin Related Compound C RS in Mobile phase

Standard stock solution: 1.0 mg/mL of USP Oxybutynin Chloride RS in Mobile phase

System suitability solution: Transfer 10.0 mL of the System suitability stock solution to a 100-mL volumetric flask, add 10.0 mL of Standard stock solution, and dilute with Mobile phase to volume.

Standard solution: 7.5 µg/mL of USP Oxybutynin Chloride RS from Standard stock solution in Mobile phase.

Sample solution: 5.0 mg/mL of Oxybutynin Chloride in Mobile phase

5.1 System suitability

Sample: System suitability solution

[Note—See Table 1 for relative retention times.]

Suitability requirements

Resolution: NLT 1.1 between oxybutynin related compound B and oxybutynin related compound C

Relative standard deviation: NMT 2.0% for the oxybutynin peak

5.2 Analysis

Samples: Standard solution and Sample solution

Record the chromatograms for a total time of NLT twice the retention time of the oxybutynin peak.

Calculate the percentage of each impurity in the portion of Oxybutynin Chloride taken:

Result = (rU /rS) × (CS /CU ) × (1/F) × 100

rU = peak response of each impurity from the Sample solution

rS = peak response of oxybutynin from the Standard solution

CS = concentration of USP Oxybutynin Chloride RS in the Standard solution (mg/mL)

CU = concentration of Oxybutynin Chloride in the Sample solution (mg/mL)

F = relative response factor for each impurity (see Table 1)

Acceptance criteria: See Table 1.

Table 1

Name

Relative Retention Time

Relative Response Factor

Acceptance Criteria, NMT (%)

Oxybutynin related compound Aa 

0.08 

1.4 

0.5

Diphenyl analog of oxybutynin chlorideb 

0.37 

2.7 

0.1

Oxybutynin related compound Bc 

0.65 

1.3 

1.0

Oxybutynin related compound Cd 

0.79 

1.0 

1.0

Oxybutynin 

1.0 

— 

—

Cyclohexenyl analog of oxybutynin chloridee 

1.8 

0.4 

1.0

Ethylpropyl analog of oxybutynin chloridef 

1.9 

1.0 

0.1

Any other individual impurity 

— 

1.0 

0.1

Total impurities 

— 

—

1.0

a Phenylcyclohexylglycolic acid (cyclohexylmandelic acid, or CHMA).

b 4-(Diethylamino)but-2-ynyl 2-hydroxy-2,2-diphenylacetate.

c Methyl ester of phenylcyclohexylglycolic acid (methyl ester of cyclohexylmandelic acid, or CHMME).

d Methylethyl analog of oxybutynin chloride (4-(ethylmethylamino) but-2-ynyl (±)-2-cyclohexyl-2-hydroxy-2-phenylacetate).

e 4-(Diethylamino)but-2-ynyl (±)-2-(cyclohex-3-enyl)-2-cyclohexyl-2-hydroxyacetate.

f 4-(Ethylpropylamino)but-2-ynyl (±)-2-cyclohexyl-2-hydroxy-2-phenylacetate.

6 SPECIFIC TESTS

Loss on Drying 〈731〉

Analysis: Dry a sample at 105° for 2 h.

Acceptance criteria: NMT 3%

7 ADDITIONAL REQUIREMENTS

Packaging and Storage: Preserve in well-closed containers.

USP Reference Standards 〈11〉

USP Oxybutynin Chloride RS

USP Oxybutynin Related Compound B RS

Methyl ester of phenylcyclohexylglycolic acid, or CHMME (cyclohexyl mandelic acid methyl ester).

USP Oxybutynin Related Compound C RS

Methylethyl analog of oxybutynin chloride, or 4-(ethylmethylamino) but-2-ynyl (±) 2-cyclohexyl-2-hydroxy-2-phenylacetate hydrochloride.

vui lòng chờ tin đang tải lên

Vui lòng đợi xử lý......

0 SẢN PHẨM
ĐANG MUA
hotline
0927.42.6789