Nitrogen

If you find any inaccurate information, please let us know by providing your feedback here

Nitrogen

Ước tính: 0 phút đọc, Ngày đăng:

This article is compiled based on the United States Pharmacopeia (USP) – 2025 Edition

Issued and maintained by the United States Pharmacopeial Convention (USP)

DOWNLOAD PDF HERE

N₂    28.01

Nitrogen CAS RN®: 7727-37-9.

1 DEFINITION

Nitrogen contains NLT 99.0%, by volume, of nitrogen (N₂).

2 IDENTIFICATION

A. The flame of a burning wood splinter is extinguished when inserted into a test tube filled with Nitrogen. [Note-Exercise caution.]

3 ASSAY

3.1 Procedure

Sample: Nitrogen

Standard: Oxygen–helium certified standard (see Reagents, Indicators, and Solutions)

Chromatographic system

  • (See Chromatography 〈621〉, System Suitability.)
  • Mode: GC
  • Detector: Thermal conductivity
  • Column: 3-m length × 4-mm inside diameter: molecular sieve prepared from a synthetic alkali-metal aluminosilicate capable of absorbing molecules having diameters of up to 0.5 nm and completely separating oxygen from nitrogen
  • Carrier gas: Helium (99.99%)
  • Temperature: Thermostatically controlled

Analysis

Samples: Standard and Sample

Introduce the Samples separately into the gas chromatograph by means of a gas sampling valve.

Acceptance criteria: The peak response produced by the Sample exhibits a retention time corresponding to that produced by the Standard and is equivalent to NMT 1.0% of oxygen when compared to the peak response of the Standard, indicating NLT 99.0%, by volume, of N₂.

4 SPECIFIC TESTS

[Note-Reduce the container pressure by means of a regulator. Measure the gases with a gas volume meter downstream from the detector tube to minimize contamination or change of the specimens.]

4.1 Carbon Monoxide

Sample: 1000 ± 50 mL

Analysis: Pass the Sample through a carbon monoxide detector tube (see Reagents, Indicators, and Solutions) at the rate specified for the tube.

Acceptance criteria: NMT 10 ppm

4.2 Limit of Oxygen

Analysis: Determined as directed in the Assay

Acceptance criteria: NMT 1.0%

4.3 Odor

Analysis: Carefully open the container valve to produce a moderate flow of gas. Do not direct the gas stream toward the face, but deflect a portion of the stream toward the nose.

Acceptance criteria: No appreciable odor is discernible.

5 ADDITIONAL REQUIREMENTS

Packaging and Storage: Preserve in cylinders.