Misoprostol
If you find any inaccurate information, please let us know by providing your feedback here

Tóm tắt nội dung
This article is compiled based on the United States Pharmacopeia (USP) – 2025 Edition
Issued and maintained by the United States Pharmacopeial Convention (USP)
C22H38O5 382.53
Prost-13-en-1-oic acid, 11,16-dihydroxy-16-methyl-9-oxo-, methyl ester, (1R*,2R*,3R*,E)-;
(±)-Methyl (1R,2R,3R)-3-hydroxy-2-[(E)-(4RS)-4-hydroxy-4-methyl-1-octenyl]-5-oxocyclopentaneheptanoate
CAS RN: 59122-46-2; UNII: 0E43V0BB57.
1 DEFINITION
Misoprostol contains NLT 97.0% and NMT 102.0% of C22H38O5, calculated on the anhydrous basis.
2 IDENTIFICATION
Change to read:
A. SPECTROSCOPIC IDENTIFICATION TESTS (197), Infrared Spectroscopy: 1975 (CN 1-MAY-2020)
Sample solution: 30 mg/mL
Medium: Chloroform
B. The retention time of the major peak of the Sample solution corresponds to that of the Standard solution, as obtained in the Assay.
3 ASSAY
PROCEDURE
Mobile phase: 2,2,4-Trimethylpentane, dioxane, and acetonitrile (78:21.5:0.5)
Standard solution: 5.0 mg/mL of USP Misoprostol RS in Mobile phase
Sample solution: 5.0 mg/mL of Misoprostol in Mobile phase
Chromatographic system
(See Chromatography (621), System Suitability.)
Mode: LC
Detector: UV 210 nm
Column: 4.6-mm x 25-cm; 5-µm packing L3
Flow rate: 2 mL/min
Injection size: 20 µL
System suitability
Sample: Standard solution
[NOTE-Identify the impurities based on the retention times shown in Impurity Table 1.]
Suitability requirements
Resolution: NLT 1.2, between the second diastereomer peak for 12-epimisoprostol and the Misoprostol peak
Relative standard deviation: NMT 1.0%, for three replicate injections
Analysis
Samples: Standard solution and Sample solution
Calculate the percentage of C22H38O5, in the portion of Misoprostol taken:
Result = (ru /rs ) × (Cs /Cu ) × 100
ru = peak response of the Sample solution
rs = peak response of the Standard solution
Cs = concentration of the Standard solution (mg/mL)
Cu = concentration of the Sample solution (mg/mL)
Acceptance criteria: 97.0%–102.0% on the anhydrous basis
4 IMPURITIES
ORGANIC IMPURITIES
4.1 PROCEDURE 1
Mobile phase, Standard solution, Sample solution, Chromatographic system, and System suitability: Proceed as directed in the Assay.
Analysis
Samples: Standard solution and Sample solution
Record the chromatogram for at least 3 times the retention time of the Misoprostol peak, and measure the peak responses. Identify the impurities based on the retention times shown in Impurity Table 1.
Calculate the percentage of each impurity in the portion of Misoprostol taken:
Result = (ru /rs ) × (Cs /Cu ) × (1/F) × 100
ru = peak response of each impurity from the Sample solution
rs = peak response of the Standard solution
Cs = concentration of USP Misoprostol RS in the Standard solution (mg/mL)
Cu = concentration of Misoprostol in the Sample solution (mg/mL)
F = relative response factor (see Impurity Table 1)
Acceptance criteria
Individual impurities: See Impurity Table 1.
Total impurities: NMT 1.5%
Impurity Table 1
| Name | Relative Retention Time | Relative Response Factor | Acceptance Criteria, NMT (%) |
| A-Type misoprostola | 0.22 | 7.8 | 0.1 |
| B-Type misoprostolb | 0.33 | 0.80 | 0.1 |
| Norprostolc | 0.51 | 8.4 | 0.1 |
| 8-Epimisoprostold | 0.71 | 1.05 | 0.3 |
| 12-Epimisoprostole | 0.86 and 0.921 | 1.08 | 1.0f |
| Misoprostol | 1.0 | - | - |
| Any other individual impurity | - | 1.0 | 0.1 |
a Methyl 7-{(1R*,2S*)-2-[(E)-4-hydroxy-4-methyloct-1-enyl]-5-oxocyclopent-3-enyl}heptanoate.
b (E)-Methyl 7-[2-(4-hydroxy-4-methyloct-1-enyl)-5-oxocyclopent-1-enyl]heptanoate.
c Methyl 7-(3-hydroxy-5-oxocyclopent-1-enyl)heptanoate.
d Methyl (1S*,2R*,3R*)-3-hydroxy-2-[(E)-4-hydroxy-4-methyl-1-octenyl]-5-oxocyclopentaneheptanoate.
e Methyl (1S*,2R*,3S*)-3-hydroxy-2-[(E)-4-hydroxy-4-methyl-1-octenyl]-5-oxocyclopentaneheptanoate.
f 12-Epimisoprostol consists of two diastereomers that are separated under these conditions; integrate both peaks together for the impurity calculations.
4.2 Procedure 2: Content of Diastereomers
Mobile phase: Hexane, Ethanol, and isopropyl alcohol (94:4:2)
Sample solution: 1.0 mg/mL of Misoprostol in Mobile phase
Chromatographic system
(See Chromatography 〈621〉,
Detector: UV 205 nm
Column: 4.6-mm × 25-cm; 5-µm packing L3
Column temperature: 40°
Flow rate: 1 mL/min
Injection size: 20 µL
System suitability
Sample: Sample solution
[Note—Identify the components based on their relative retention times which are about 0.92 for the rst diastereomer peak and 1.0 for the
second diastereomer peak.]
Suitability requirements
Resolution: NLT 2.0, between the two diastereomer peaks
Relative standard deviation: NMT 2.0% from the area of the rst diastereomer peak
Analysis
Sample: Sample solution
Calculate the fraction of the rst diastereomer in the portion of Misoprostol taken:
Result = r1 /(r1 + r2 )
r1 = peak response for the rst diastereomer
r2 = peak response for the second diastereomer
Acceptance criteria
Fraction of the rst diastereomer: 0.51–0.56
5 SPECIFIC TESTS
Water Determination, Method Ic〈921〉: NMT 0.5%
6 ADDITIONAL REQUIREMENTS
Packaging and Storage: Preserve in tight containers, and store in a freezer.
USP Reference Standards 〈11〉
USP Misoprostol RS