Indene
If you find any inaccurate information, please let us know by providing your feedback here

This article is compiled based on the United States Pharmacopeia (USP) – 2025 Edition
Issued and maintained by the United States Pharmacopeial Convention (USP)
C9H8 116.16 CAS RN: 95-13-6.—Colorless liquid.
Assay: Inject an appropriate specimen into a suitable gas chromatograph (see Chromatography (621)) equipped with a flame-ionization detector, helium being used as the carrier gas. The following conditions have been found suitable: a 0.25 - mm x 10 - m capillary column coated with a 1-µm layer of methylsilicone; the injection port temperature is maintained at 200°; the detector temperature is maintained at 300°; the column temperature is maintained at 100° and programmed to rise 10° per minute to 250°. The area of the indene peak is not less than 99% of the total peak area.
REFRACTIVE INDEX (831): between 1.5749 and 1.5769 at 20°.