Hydrogenated Polydextrose
If you find any inaccurate information, please let us know by providing your feedback here

This article is compiled based on the United States Pharmacopeia (USP) – 2025 Edition
Issued and maintained by the United States Pharmacopeial Convention (USP)
1 DEFINITION
Hydrogenated Polydextrose is obtained by transition metal catalytic hydrogenation of Polydextrose in aqueous solution. It contains NLT 90.0% of dextrose polymer units, calculated on the anhydrous and ash-free basis. The polymer chain end groups are mainly sorbitol-terminated.
2 IDENTIFICATION
A.
Sample: 1 drop of a solution (1 in 10)
Analysis: Add 4 drops of 5% phenol solution to the Sample and then rapidly add 15 drops of sulfuric acid TS.
Acceptance criteria: A deep yellow to orange color is produced.
B.
Sample: 1 mL of a solution (1 in 10)
Analysis: With vigorous swirling, add 1 mL of acetone to the Sample.
Acceptance criteria: The solution remains clear.
C.
Sample: Solution obtained in Identification B
Analysis: With vigorous swirling, add 2 mL of acetone to the Sample.
Acceptance criteria: A heavy, milky turbidity develops immediately.
D.
Sample: 1 mL of a solution (1 in 50)
Analysis: Add 4 mL of alkaline cupric citrate TS to the Sample. Boil vigorously for 2–4 min. Remove from heat, and allow the precipitate (if any) to settle.
Acceptance criteria: The supernatant is blue or blue-green.
E. Meets the requirements for dextrose in Organic Impurities, Procedure 2, Limit of Monomers
F. Chromatographic Identity
Analysis: Proceed as directed in the Assay.
Acceptance criteria: The retention time of the major peak of the Sample solution corresponds to that of the Standard solution, as obtained in the Assay.
3 ASSAY
Procedure
Mobile phase: 0.001 N sulfuric acid, prepared as follows. Cautiously transfer 3 mL of sulfuric acid into a 100-mL volumetric flask containing approximately 80 mL of water, dissolve, and dilute with water to volume. Pipet 1 mL of the resulting solution into a 1000-mL volumetric flask, and dilute with water to volume. Proportionally larger volumes of the second dilution may be prepared if desired.
Standard solution: 4.0 mg/mL of USP Hydrogenated Polydextrose RS in Mobile phase
Sample solution: 4.0 mg/mL of Hydrogenated Polydextrose in Mobile phase
Chromatographic system
(See Chromatography 〈621〉, System Suitability.)
Mode: LC
Detector: Refractive index
Detector temperature: 35 ± 0.1°
Columns
Guard: 4.6-mm × 3.0-cm; packing L17
Analytical: 7.8-mm × 30-cm; packing L17
Flow rate: 0.6 mL/min
Injection volume: 20 µL
System suitability
Sample: Standard solution
Suitability requirements: Relative standard deviation: NMT 2.0%
Analysis
Samples: Standard solution and Sample solution.
[Note—Integrate and include smaller peaks eluted on the tailing of the Hydrogenated Polydextrose to be included as a part of the Assay.]
Calculate the percentage of dextrose polymer units in the portion of Hydrogenated Polydextrose taken:
Result = (r₁/r₂) × (C₁/C₂) × 100
where:
r₁ = peak response of dextrose polymer units from the Sample solution
r₂ = peak response of dextrose polymer units from the Standard solution
C₁ = concentration of USP Hydrogenated Polydextrose RS in the Standard solution (mg/mL)
C₂ = concentration of Hydrogenated Polydextrose in the Sample solution (mg/mL)
Acceptance criteria: NLT 90.0% on the anhydrous and ash-free basis
4 IMPURITIES
Residue on Ignition 〈281〉: NMT 0.3%
Limit of Lead
[Note—Use reagent-grade chemicals with a lead content of as low as possible, as well as high-purity water and gases. Before use in this analysis, rinse all glassware and plasticware twice with 10% nitric acid and twice with 10% hydrochloric acid, and then rinse them thoroughly with Purified Water.]
Matrix modifier solution: 10.0 mg/mL of dibasic ammonium phosphate
Lead nitrate stock solution: Dissolve 159.8 mg of lead nitrate in 100 mL of water to which has been added 1 mL of nitric acid, then dilute with water to 1000 mL. Prepare and store this solution in glass containers free from soluble lead salts.
Standard lead solution: On the day of use, dilute 10.0 mL of the Lead nitrate stock solution with water to 100.0 mL. Each milliliter of the Standard lead solution contains the equivalent of 10 µg of lead.
Standard solution A: 0.02 µg/mL of lead, from the Standard lead solution in water
Standard solution B: 0.05 µg/mL of lead, from the Standard lead solution in water
Standard solution C: 0.1 µg/mL of lead, from the Standard lead solution in water
Standard solution D: 0.2 µg/mL of lead, from the Standard lead solution in water
Standard solution E: 0.5 µg/mL of lead, from the Standard lead solution in water
Sample solution: Transfer 1.0 g of Hydrogenated Polydextrose, weighed and calculated on the anhydrous and ash-free basis, into a 10-mL volumetric flask, dissolve in and dilute with water to volume.
Spiked sample solution: Transfer 1.0 g of Hydrogenated Polydextrose, weighed and calculated on the anhydrous and ash-free basis, into a 10-mL volumetric flask, and dissolve in water. Add 100 µL of the Standard lead solution, and dilute with water to volume. This solution contains 0.1 µg/mL of added lead.
Instrumental conditions
(See Atomic Absorption Spectroscopy 〈852〉.)
Mode: Graphite furnace atomic absorption spectrophotometer, equipped with a pyrolytic tube with a platform
Lamp: A lead hollow-cathode lamp, using a slit width of 0.7 mm (set low) and a deuterium arc lamp for background correction
Analytical wavelength: Lead emission line of 283.3 nm
Autosampler: Sample volume: 10 µL
Alternative volume: 10 µL of Matrix modifier solution
Furnace program: See the temperature program in Table 1.
| Step | Dry | Char | Atomize | Clean | Recharge |
| Temperature (°) | 130 | 800 | 2400 | 2600 | 20 |
| Ramp time (s) | 20 | 20 | 0 | 1 | 2 |
| Hold time (s) | 40 | 40 | 6 | 5 | 20 |
| Argon flow rate (mL/min) | 300 | 300 | 50 | 300 | 300 |
Analysis
Samples: 10 µL of the Matrix modifier solution was added into each of the 10-µL aliquots of the 5 Standard solutions (Standard solutions A–E), a mixture of 10 µL of the Matrix modifier solution and 10 µL of the Sample solution, and a mixture of 10 µL of the Matrix modifier solution and 10 µL of the Spiked sample solution.
Concomitantly determine the absorbances of the Samples using the Instrumental conditions described. Plot the absorbance of each Standard solution, compensated for background correction, versus its content of lead, in µg/mL, and draw the best straight line fitting the five points. From this plot, determine the concentrations, C₁ and C₂, in µg/mL, of lead in the Sample solution and the Spiked sample solution, respectively.
Calculate the percentage recovery taken:
Result = [(C₂ − C₁)/A] × 100
A = quantity of lead added to the Spiked sample solution, 0.1 µg/mL
Calculate the content, in µg/g, of lead in the portion of Hydrogenated Polydextrose taken:
Result = (C₁/W) × V
W = weight of Hydrogenated Polydextrose taken to prepare the Sample solution (g)
V = volume of the Sample solution, 10 mL
Acceptance criteria: NMT 0.5 µg/g; recovery is 80%–120%
Limit of Nickel
Digest solution: Add 50 mL of nitric acid, ultratrace to a 1000-mL volumetric flask containing 500 mL of water. Mix and dilute with water to volume.
Nickel standard stock solution: 10 μg/mL of ICP Nickel (or multi-element) standard in 5% nitric acid solution.
Standard solution A: Pipet 1 mL from the Nickel standard stock solution to a 100-mL volumetric flask. Dilute with Digest solution to volume and mix. This solution contains 0.1 μg/mL of nickel.
Standard solution B: Pipet 2 mL from the Nickel standard stock solution to a 100-mL volumetric flask. Dilute with Digest solution to volume and mix. This solution contains 0.2 μg/mL of nickel.
Standard solution C: Pipet 5 mL from the Nickel standard stock solution to a 100-mL volumetric flask. Dilute with Digest solution to volume and mix. This solution contains 0.5 μg/mL of nickel.
Sample solution: Transfer 5 g of Hydrogenated Polydextrose into a 100-mL volumetric flask, and dissolve in and dilute with Digest solution to volume.
Blank solution: Use a fresh aliquot of the Digest solution.
Chromatographic system
(See Plasma Spectrochemistry 〈730〉.)
Mode: ICP–OES
Emission wavelength: 352.4 nm for nickel. Set the sample read time and other instrument parameters as appropriate or as recommended by the instrument manufacturer.
System suitability
Samples: Standard solution A, Standard solution B, and Blank solution
Suitability requirements: [Note—Instrument performance must be verified to conform to the manufacturer's specifications for resolution and sensitivity. Before analyzing samples, the instrument must pass a suitable performance check.]
Correlation coefficient: NLT 0.995, determined from the calibration curve constructed in the Analysis
Analysis
Samples: Standard solutions A–C and Blank solution
[Note—The following analysis is described for one type of ICP–OES instrument. If a different ICP–OES instrument is used, follow the instrument manufacturer's recommendations for operation.]
Take 3 replicate scans with the integration set as recommended by the instrument manufacturer. Follow the instrument manufacturer's recommendations for delivering the sample. Flush the samples through the system before analysis. Program a read delay into the sampling routine to allow for fluid flow equilibration after the flush, before the first analytical read of the sample. Between samples, wash the pumping system by pushing the Blank solution.
Calibration curve: Generate the calibration curve using the Blank solution and Standard solutions A–C as follows. Construct a calibration curve by plotting the corrected nickel intensity versus the known concentrations, in μg/mL, of the nickel. Similarly, analyze the Sample solution. Plot the intensity of the emission of the Sample solution on the calibration curve. Determine the concentration of nickel (C), in μg/mL, in the Sample solution through the calibration curve.
Calculate the content, in µg/g, of nickel in the portion of Hydrogenated Polydextrose taken:
Result = (V × C)/W
V = volume of the Sample solution, 100 mL
C = concentration of nickel in the Sample solution (μg/mL)
W = weight of Hydrogenated Polydextrose (g) in the Sample solution
Acceptance criteria: NMT 2 µg/g
Organic Impurities
Procedure 1: Limit of 5-Hydroxymethylfurfural and Related Compounds
Sample solution: 1.0 g of Hydrogenated Polydextrose, weighed and calculated on the anhydrous and ash-free basis, diluted with water to 100 mL
Analysis: Determine the absorbance of the Sample solution in a 1-cm quartz cell at 283 nm, with a suitable spectrophotometer, using water as the blank.
Calculate the percentage of 5-hydroxymethylfurfural and related compounds in the portion of Hydrogenated Polydextrose taken:
Result = (V × M × A)/(ε × L × W) × 100
V = volume of the Sample solution, 0.1 L
M = molecular weight of 5-hydroxymethylfurfural, 126 g/mol
A = absorbance of the Sample solution
ε = molar extinction coefficient of 5-hydroxymethylfurfural at a wavelength of 283 nm, 16,830 L·mol⁻¹·cm⁻¹
L = path length of the spectrophotometer cell (cm)
W = weight of Hydrogenated Polydextrose taken to prepare the Sample solution (g)
Acceptance criteria: NMT 0.1%
Procedure 2: Limit of Monomers
Mobile phase, Sample solution, and Chromatographic system: Proceed as directed in the Assay.
Standard solution: 0.08 mg/mL of each for USP 1,6-Anhydro-d-glucose RS and USP Sorbitol RS and 0.04 mg/mL of USP Dextrose RS in Mobile phase
System suitability
Sample: Standard solution
[Note—See the relative retention times in Table 2.]
| Name | Relative Retention Time |
| Dextrose (Glucose) | 0.7 |
| Sorbitol | 0.8 |
| An isomer of 1,6-anhydro-d-glucose | 0.9 |
| (d-anhydroglucose furanose form) | |
| 1,6-Anhydro-d-glucose (levoglucosan) | 1.0 |
| (d-anhydroglucose pyranose form) |
Suitability requirements
Resolution: NLT 1.0
Relative standard deviation: NMT 5.0%
Analysis
Samples: Standard solution and Sample solution
Use the peak response of USP 1,6-Anhydro-d-glucose RS in the Standard solution for calculation of the percentage of the isomer of 1,6-anhydro-d-glucose in the Sample solution.
Calculate the percentage of each monomer in the portion of Hydrogenated Polydextrose taken:
Result = (r₁/r₂) × (C₁/C₂) × 100
r₁ = peak response for the respective monomer from the Sample solution
r₂ = peak response for the respective monomer from the Standard solution
C₁ = concentration of the respective standard monomer in the Standard solution (mg/mL)
C₂ = concentration of Hydrogenated Polydextrose in the Sample solution (mg/mL)
Acceptance criteria
[Note—In the case of 1,6-anhydro-d-glucose, the peak areas for the pyranose and furanose forms are combined.]
1,6-Anhydro-d-glucose: NMT 4.0%
Sorbitol: NMT 5.75%
Dextrose: NMT 0.25%
5 SPECIFIC TESTS
Molecular Weight Limit
[Note—Molecular weights (Mp) for the standards can be selected as available commercially while maintaining the required calibration range.]
Mobile phase: Dissolve 35.0 g of sodium nitrate and 1.0 g of sodium azide in 100 mL of water. Dilute with water to 4 L. Pass through a filter of 0.45-µm or finer pore size, and degas by applying an aspirator vacuum for 30 min. The resulting Mobile phase is 0.1 N sodium nitrate containing 0.025% sodium azide.
Standard solution: Transfer 20 mg each of USP Dextrose RS, stachyose, and 5800-, 23,700-, and 100,000-molecular weight (MW) pullulan standards into a 10-mL volumetric flask. Dissolve in and dilute with Mobile phase to volume. Pass through a syringe filter of 0.45-µm or finer pore size into a suitable autosampler vial, and seal.
Sample solution: Transfer 50 mg of Hydrogenated Polydextrose into a 10-mL volumetric flask. Dissolve in and dilute with Mobile phase to volume. Pass through a syringe filter of 0.45-µm or finer pore size into a suitable autosampler vial, and seal.
Chromatographic system
(See Chromatography 〈621〉, System Suitability.)
Mode: LC
Detector: Refractive index, maintained at a temperature of 35 ± 0.1°
Column: 7.8-mm × 30-cm; packing L39
Column temperature: 45°
Flow rate: 0.8 mL/min
[Note—After installation of a new column, pump Mobile phase through the column overnight at a rate of 0.3 mL/min. Before calibration or analysis, increase the flow slowly over a 1-min period to 0.8 mL/min. Continue to pump Mobile phase through the column at this flow rate for at least 1 h before the first injection. Check the flow gravimetrically, and adjust it if necessary. Reduce the flow rate to about 0.1 mL/min when the system is not in use.]
Injection volume: 50 µL
System suitability
Sample: Standard solution
Chromatograph 5 replicate injections of the Standard solution, allowing 15 min between injections, and record the retention times of the components of the Standard solution.
Insert the average retention time along with the molecular weight of each component in the Standard solution into the calibration table of the molecular weight distribution software. Check the regression results for a cubic fit of the calibration points, and obtain a correlation coefficient, R, for the line.
Suitability requirements:
Retention time: The retention times for each component determined on replicate injections agree within ±2 s.
Resolution: Dextrose and stachyose are baseline resolved from one another and from the 5800-MW pullulan standard.
[Note—Prominent negative baseline valleys are usually observed between the peaks for the 5800-, 23,700-, and 100,000-MW pullulan standards.]
Correlation coefficient R: NLT 0.9999
Analysis
Samples: Standard solution and Sample solution
Use the molecular weight distribution software of the data reduction system to generate a molecular weight distribution plot of Hydrogenated Polydextrose.
Acceptance criteria: No measurable peak above a molecular weight of 22,000 is found.
pH 〈791〉: 5.0–7.0, in a solution (1 in 10)
Water Determination 〈921〉, Method I:
[Note—Temperature can be adjusted depending on the titrator's capability.] NMT 4.0%.
Use a mixture of Hydranal Solvent and Hydranal Formamide dry (2:1) as a solvent. Perform the titration at 50° in a jacketed beaker.
6 ADDITIONAL REQUIREMENTS
Packaging and Storage: Preserve in tight, light-resistant containers. Store in a cool and dry place.
USP Reference Standards 〈11〉
USP 1,6-Anhydro-d-glucose RS
USP Dextrose RS
USP Hydrogenated Polydextrose RS
USP Sorbitol RS

