1 DEFINITION 

Clioquinol and Hydrocortisone Cream contains NLT 90.0% and NMT 110.0% of the labeled amounts of clioquinol (C9H5ClINO) and hydrocortisone (C21H30O5) in a suitable cream base. 

2 IDENTIFICATION 

A. The retention time of the clioquinol peak of the Sample solution corresponds to that of the Standard solution, as obtained in the Assay for Clioquinol. 

B. The retention time of the hydrocortisone peak of the Sample solution corresponds to that of the Standard solution, as obtained in the Assay for Hydrocortisone. 

3 ASSAY 

Clioquinol 

Internal standard solution: 2 mg/mL of pyrene in pyridine 

Standard stock solution: 3 mg/mL of USP Clioquinol RS in a mixture of pyridine and n-hexane (4:1) 

Standard solution: Transfer 1.0 mL of the Standard stock solution, 1.0 mL of N,O-bis(trimethylsilyl)acetamide, and 1.0 mL of Internal standard solution to a suitable screw-capped glass vial fitted with a polytef-lined septum, and mix. Heat on a water bath at 50° for 15 min, and cool to room temperature. 

Sample solution: Transfer nominally 150 mg of clioquinol from Cream to a 60-mL separator. Place the separator on its side in a vacuum oven at 45° for 4 h. Remove the separator, cool to room temperature, and add 15.0 mL of a mixture of pyridine and hexane (4:1). Insert the stopper in the separator, and mix until the specimen is completely dispersed. Transfer the contents of the separator to a 50-mL volumetric  flask, rinse the separator with two 15-mL portions of a mixture of pyridine and hexane (4:1), collecting the rinsings in the volumetric flask, and dilute with the same solvent mixture to volume. Immediately transfer 1 mL of this solution to a dry, screw-capped glass vial, and evaporate with the aid of gentle heat and a stream of nitrogen to dryness. Dissolve the residue in 1.0 mL of a mixture of pyridine and hexane (4:1), add 1 mL each of N,O-bis(trimethylsilyl)acetamide and Internal standard solution to the screw-capped glass vial fitted with a polytef-lined septum, and mix. Heat on a water bath at 50° for 15 min, and cool to room temperature. 

Chromatographic system 

(See Chromatography 〈621〉, System Suitability.) 

Mode: GC 

Detector: Flame ionization 

Column: 2-mm × 1.8-m; packed with 3% liquid phase G3 on 80- to 100-mesh support SlAB 

Temperatures 

Column: 165° 

Injection port: 170° 

Detector: 250° 

Carrier gas: Dry helium 

Flow rate: 30 mL/min 

Injection volume: 1 µL 

System suitability 

Sample: Standard solution 

[Note—The relative retention times for clioquinol and pyrene are 0.6 and 1.0, respectively.] 

Suitability requirements 

Resolution: NLT 3.0 between the analyte and internal standard peaks 

Relative standard deviation: NMT 2.0% 

Analysis 

Samples: Standard solution and Sample solution 

Cream Record the chromatograms to obtain NLT 40% of maximum recorder response, and measure the peak response of each component. Calculate the percentage of the labeled amount of clioquinol (C9H5ClINO) in the portion of Cream taken: 

Result = (RU/RS) × (CS/CU) × 100 

rU = peak response ratio of clioquinol to the internal standard from the Sample solution

rS = peak response ratio of clioquinol to the internal standard from the Standard solution

CS = concentration of USP Clioquinol RS in the Standard solution (mg/mL)

CU = nominal concentrationof clioquinol in the Sample solution (mg/mL)

Acceptance criteria: 90.0%–110.0% 

Hydrocortisone 

Mobile phase: Acetonitrile, methanol, and water (1:1:2.75) 

Standard stock solution: 1 mg/mL of USP Hydrocortisone RS in alcohol 

Standard solution: 100 µg/mL of USP Hydrocortisone RS in alcohol from the Standard stock solution 

Sample solution: Transfer nominally 10 mg of hydrocortisone from Cream to a 50-mL centrifuge tube. Add 30 mL of alcohol, and heat on a steam bath just to boiling. Shake for 15 min, and centrifuge. Transfer the supernatant extract to a 100-mL volumetric flask. Repeat the extraction with two 20-mL portions of alcohol, combining the extracts in the 100-mL volumetric flask. Add alcohol to volume, mix, and lter. System suitability stock solution: 0.5 mg/mL of methylparaben in alcohol 

System suitability solution: Transfer 2 mL of System suitability stock solution and 20 mL of Standard stock solution into a 200-mL volumetric flask, and dilute with alcohol to volume. 

Chromatographic system 

(See Chromatography 〈621〉, System Suitability.) 

Mode: LC 

Detector: UV 254 nm 

Columns 

Guard: Packing L2 

Analytical: 3.9-mm × 30-cm; packing L1 

Flow rate: 1 mL/min 

Injection volume: 10 µL 

System suitability 

Sample: System suitability solution 

[Note—The relative retention times for methylparaben and hydrocortisone are 0.6 and 1.0, respectively.] Suitability requirements 

Resolution: NLT 2.0 between the hydrocortisone and methylparaben peaks 

Relative standard deviation: NMT 2.0% 

Analysis 

Samples: Standard solution and Sample solution 

Calculate the percentage of the labeled amount of hydrocortisone (C21H30O5 ) in the portion of Cream taken:

Result = (rU/rS) × (CS/CU) × 100 

rU = peak response from the Sample solution

rS = peak response from the Standard solution

CS = concentrationof USP Hydrocortisone RS in the Standard solution (mg/mL)

CU = nominal concentration of hydrocortisone in the Sample solution (mg/mL)

F = conversion factor, 0.001 mg/µg 

Acceptance criteria: 90.0%–110.0% 

4 PERFORMANCE TESTS 

Minimum Fill 〈755〉: Meets the requirements 

5 ADDITIONAL REQUIREMENTS 

Packaging and Storage: Preserve in collapsible tubes or in tight, light-resistant containers. 

USP Reference Standards 〈11〉

USP Clioquinol RS