Atomoxetine Hydrochloride
If you find any inaccurate information, please let us know by providing your feedback here

This article is compiled based on the United States Pharmacopeia (USP) – 2025 Edition
Issued and maintained by the United States Pharmacopeial Convention (USP)
Atomoxetine Hydrochloride
Change to read:
C₁₇H₂₁NO · HCl 291.82
Benzenepropanamine, N-methyl-γ-(2-methylphenoxy)-, hydrochloride, (-);
(-)-N-Methyl-3-phenyl-3-(o-tolyloxy)propylamine hydrochloride;
(R)-N-Methyl-3-phenyl-3-(2-tolyloxy)propylamine hydrochloride
CAS RN®: 82248-59-7; UNII: 57WVB6I2W0.
1 DEFINITION
Atomoxetine Hydrochloride contains NLT 98.0% and NMT 102.0% of atomoxetine hydrochloride (C₁₇H₂₁NO · HCl), calculated on the dried basis.
2 IDENTIFICATION
A. Spectroscopic Identification Tests 〈197〉, Infrared Spectroscopy: 197K
B. The retention time of the major peak of the Sample solution corresponds to that of the atomoxetine R-isomer from the System suitability solution, as obtained in the test for Organic Impurities, Procedure 2.
C. Identification Tests—General 〈191〉, Chemical Identification Tests, Chloride: Meets the requirements
3 ASSAY
Procedure
Solution A: 280 g/L of potassium hydroxide in water
Buffer: 2.9 g/L of phosphoric acid in water. Adjust with Solution A to a pH of 2.5. To 1 L of this solution add 5.9 g of octanesulfonic acid sodium salt monohydrate.
Mobile phase: n-Propyl alcohol and Buffer (27:73). [Note—The ratio of n-propyl alcohol in Buffer can be varied between 26:74 and 29:71 to meet system suitability requirements.]
System suitability solution: 0.1 mg/mL of USP Mandelic Acid RS, 0.15 mg/mL of USP Atomoxetine Related Compound A RS, and 0.25 mg/mL of USP Atomoxetine Hydrochloride RS in Mobile phase
Standard solution: 0.25 mg/mL of USP Atomoxetine Hydrochloride RS in Mobile phase. Sonication may be used to aid in dissolution.
Sample solution: 0.25 mg/mL of Atomoxetine Hydrochloride in Mobile phase. Sonication may be used to aid in dissolution.
Chromatographic system
(See Chromatography 〈621〉, System Suitability.)
Mode: LC
Detector: UV 215 nm
Column: 4.6-mm × 15-cm; 3.5-µm packing L7
Column temperature: 40°
Flow rate: 1 mL/min
Injection volume: 10 µL
Run time: NLT 1.3 times the retention time of atomoxetine
System suitability
Samples: System suitability solution and Standard solution
[Note—See Table 1 for the relative retention times.]
Suitability requirements
Resolution: NLT 5.0 between mandelic acid and atomoxetine related compound A, System suitability solution
Tailing factor: NMT 1.5 for atomoxetine, System suitability solution
Relative standard deviation: NMT 0.73%, Standard solution
Analysis
Samples: Standard solution and Sample solution
Calculate the percentage of atomoxetine hydrochloride (C₁₇H₂₁NO · HCl) in the portion of Atomoxetine Hydrochloride taken:
Result = (rU / rS) × (CS / CU) × 100
rU = peak response of atomoxetine from the Sample solution
rS= peak response of atomoxetine from the Standard solution
CS = concentration of USP Atomoxetine Hydrochloride RS in the Standard solution (mg/mL)
CU= concentration of Atomoxetine Hydrochloride in the Sample solution (mg/mL)
Acceptance criteria: 98.0%–102.0% on the dried basis
Atomoxetine-Hydrochloride-ttt
4 IMPURITIES
Residue on Ignition 〈281〉: NMT 0.1%
Organic Impurities, Procedure 1
[Note—It is required to perform Organic Impurities, Procedure 1 and Organic Impurities, Procedure 2.]
Buffer, Mobile phase, and System suitability solution: Prepare as directed in the Assay.
Sensitivity solution: 0.0013 mg/mL of USP Atomoxetine Hydrochloride RS in Mobile phase
Standard solution: 0.0025 mg/mL of USP Atomoxetine Hydrochloride RS in Mobile phase
Sample solution: 2.5 mg/mL of Atomoxetine Hydrochloride in Mobile phase
Chromatographic system: Proceed as directed in the Assay, except for Run time.
Run time: NLT 2.6 times the retention time of atomoxetine
System suitability
Samples: System suitability solution, Sensitivity solution, and Standard solution
[Note—See Table 1 for the relative retention times.]
Suitability requirements
Resolution: NLT 5.0 between mandelic acid and atomoxetine related compound A, System suitability solution
Tailing factor: NMT 1.5 for atomoxetine, System suitability solution
Relative standard deviation: NMT 5%, Standard solution
Signal-to-noise ratio: NLT 10, Sensitivity solution
Analysis
Samples: Standard solution and Sample solution
Calculate the percentage of any individual impurity in the portion of Atomoxetine Hydrochloride taken:
Result = (rU / rS) × (CS / CU)× 100
rU= peak response of each individual impurity from the Sample solution
rS= peak response of atomoxetine from the Standard solution
CS = concentration of USP Atomoxetine Hydrochloride RS in the Standard solution (mg/mL)
CU= concentration of Atomoxetine Hydrochloride in the Sample solution (mg/mL)
Acceptance criteria: See Table 1. The reporting threshold is 0.05%.
| Name | Relative Retention Time | Acceptance Criteria, NMT (%) |
| Mandelic acid | 0.20 | 0.10 |
| Atomoxetine related compound A | 0.27 | 0.10 |
| Desmethyl atomoxetineᵃ | 0.73 | 0.3 |
| Atomoxetine | 1.0 | — |
| Any individual unspecified impurity | — | 0.10 |
| Total impurities | — | 0.5 |
ᵃ (R)-N-Methyl-3-phenoxy-3-phenylpropan-1-amine.
Organic Impurities, Procedure 2
Mobile phase: Isopropyl alcohol, diethylamine, trifluoroacetic acid, and chromatographic solvent hexane (150: 1.5: 2.0: 846.5)
System suitability solution: 3.5 mg/mL of USP Atomoxetine Hydrochloride RS, 17.5 µg/mL of USP Atomoxetine S-Isomer RS, and 3.5 µg/mL of USP Atomoxetine Related Compound B RS, prepared by first dissolving the Reference Standards in absolute alcohol, using 25% of the final volume. Dilute with chromatographic solvent hexane to volume.
Sensitivity solution: 0.0018 mg/mL of USP Atomoxetine Hydrochloride RS prepared by first dissolving it in absolute alcohol, using 25% of the final volume. Dilute with chromatographic solvent hexane to volume.
Sample solution: 3.5 mg/mL of Atomoxetine Hydrochloride prepared by first dissolving it in absolute alcohol, using 25% of the final volume. Dilute with chromatographic solvent hexane to volume.
Chromatographic system
(See Chromatography 〈621〉, System Suitability.)
Mode: LC
Detector: UV 273 nm
Column: 4.6-mm × 25-cm; 5-µm packing L40
Flow rate: 1 mL/min
Injection volume: 10 µL
Run time: NLT 1.3 times the retention time of atomoxetine
System suitability
Samples: System suitability solution and Sensitivity solution
[Note—See Table 2 for the relative retention times.]
Suitability requirements
Resolution: NLT 1.75 between atomoxetine S-isomer and atomoxetine related compound B, System suitability solution
Tailing factor: NMT 1.8 for atomoxetine, System suitability solution
Signal-to-noise ratio: NLT 10, Sensitivity solution
Analysis
Sample: Sample solution
Calculate the percentage of atomoxetine related compound B, atomoxetine related compound C, and atomoxetine S-isomer in the portion of Atomoxetine Hydrochloride taken:
Result = (rU / rS)× 100
rU = peak response of each individual impurity from the Sample solution
rS= sum of all the peak responses of atomoxetine related compound B, atomoxetine related compound C, atomoxetine S-isomer, and atomoxetine from the Sample solution
Acceptance criteria: See Table 2. The reporting threshold is 0.05%.
| Name | Relative Retention Time | Acceptance Criteria, NMT (%) |
| Atomoxetine S-isomer | 0.47 | 0.5 |
| Atomoxetine related compound Cᵃ | 0.52 | 0.1 |
| Atomoxetine related compound B | 0.56 | 0.1 |
| Atomoxetine | 1.0 | — |
ᵃ (R)-N-Methyl-3-phenyl-3-(4-tolyloxy)propan-1-amine; also known as (R)-N-Methyl-3-phenyl-3-(p-tolyloxy)propan-1-amine.
5 SPECIFIC TESTS
Loss on Drying 〈731〉
Analysis: Dry under vacuum at 105° for 2 h.
Acceptance criteria: NMT 0.5%
6 ADDITIONAL REQUIREMENTS
Packaging and Storage: Preserve in well-closed containers. Store at room temperature.
Change to read:
USP Reference Standards 〈11〉
USP Atomoxetine Hydrochloride RS
USP Atomoxetine Related Compound A RS
3-(Methylamino)-1-phenylpropan-1-ol.
C₈H₁₁NO₂ 165.23
USP Atomoxetine Related Compound B RS
(R)-N-Methyl-3-phenyl-3-(3-tolyloxy)propan-1-amine hydrochloride.
C₁₇H₂₁NO · HCl 291.82
USP Atomoxetine S-Isomer RS
(S)-N-Methyl-3-phenyl-3-(2-tolyloxy)propan-1-amine hydrochloride; also known as (S)-N-Methyl-3-phenyl-3-(o-tolyloxy)propan-1-amine hydrochloride.
C₁₇H₂₁NO · HCl 291.82
USP Mandelic Acid RS
2-Hydroxy-2-phenylacetic acid.
C₈H₈O₃ 152.15