Atenolol
If you find any inaccurate information, please let us know by providing your feedback here
This article is compiled based on the United States Pharmacopeia (USP) – 2025 Edition
Issued and maintained by the United States Pharmacopeial Convention (USP)
Atenolol
Change to read:
C₁₄H₂₂N₂O₃ 266.34
Benzeneacetamide, 4-[2-hydroxy-3-[(1-methylethyl)amino]propoxy]-;
2-{4-[2-Hydroxy-3-(isopropylamino)propoxy]-phenyl}acetamide
CAS RN®: 29122-68-7; UNII: 50VV3VW0TI.
1 DEFINITION
Atenolol contains NLT 98.0% and NMT 102.0% of atenolol (C₁₄H₂₂N₂O₃), calculated on the dried basis.
2 IDENTIFICATION
A. Spectroscopic Identification Tests 〈197〉, Infrared Spectroscopy: 197K
Change to read:
B. ▲The retention time of the major peak of the Sample solution corresponds to that of the Standard solution, as obtained in the Assay.▲ (USP 1-May-2022)
3 ASSAY
Change to read:
Procedure
Buffer: 3.4 g/L of potassium phosphate, monobasic, 1.25 g/L of octanesulfonic acid sodium salt, and 0.5 g/L of tetrabutylammonium hydrogen sulfate
0.8 M phosphoric acid solution: Dilute 5.2 mL of phosphoric acid in 100 mL of water.
Mobile phase: Methanol, tetrahydrofuran, and Buffer (18:2:80). Adjust with 0.8 M phosphoric acid solution to a pH of 3.0.
Standard solution: 0.01 mg/mL of USP Atenolol RS in Mobile phase. Sonication may be necessary for complete dissolution.
Sample solution: 0.01 mg/mL of Atenolol in Mobile phase. Sonication may be necessary for complete dissolution.
Chromatographic system
(See Chromatography 〈621〉, System Suitability.)
Mode: LC
Detector: UV 226 nm
Column: 4.6-mm × 15-cm; 5-µm packing L1
Flow rate: 1 mL/min
Injection volume: 10 µL
Run time: NLT 2 times the retention time of atenolol
System suitability
Sample: Standard solution
Suitability requirements
Tailing factor: NMT 2.0
Relative standard deviation: NMT 0.73%▲ (USP 1-May-2022)
Analysis
Samples: Standard solution and Sample solution
Calculate the percentage of atenolol (C₁₄H₂₂N₂O₃) in the portion of Atenolol taken:
Result = (rU / rS) × (CS / CU) × 100
rU = peak response of atenolol from the Sample solution
rS = peak response of atenolol from the Standard solution
CS = concentration of USP Atenolol RS in the Standard solution (mg/mL)
CU = concentration of Atenolol in the Sample solution (mg/mL)
Acceptance criteria: 98.0%–102.0% on the dried basis
4 IMPURITIES
Residue on Ignition 〈281〉: NMT 0.2%
Change to read:
Chloride and Sulfate 〈221〉, Chloride
Standard solution: 1.4 mL of 0.020 N hydrochloric acid in 100 mL of 0.15 N nitric acid▲ (USP 1-May-2022)
Sample solution: 1.0 g in 100 mL of 0.15 N nitric acid
Acceptance criteria: The Sample solution shows no more turbidity with 1 mL of silver nitrate TS than the Standard solution▲ (USP 1-May-2022) (0.1%).
Change to read:
Organic Impurities
Buffer and Mobile phase: Prepare as directed in the Assay.
Impurity stock solutions 1–3: 0.1 mg/mL each of USP Atenolol Related Compound A RS, USP Atenolol Related Compound B RS, and USP Atenolol Related Compound F RS prepared as follows. Separately transfer an appropriate quantity of USP Atenolol Related Compound A RS, USP Atenolol Related Compound B RS, and USP Atenolol Related Compound F RS to individual suitable volumetric flasks. Add methanol to 10% of the final volume and sonicate to dissolve. Dilute with Mobile phase to volume.
Impurity stock solution 4: 0.1 mg/mL of USP Atenolol Related Compound E RS prepared as follows. Transfer an appropriate quantity of USP Atenolol Related Compound E RS to a suitable volumetric flask. Add acetonitrile to 50% of the final volume and sonicate to dissolve. Dilute with water to volume.
Sensitivity solution: 0.5 μg/mL of USP Atenolol RS in Mobile phase
Standard solution: 0.01 mg/mL of USP Atenolol RS and 0.005 mg/mL each of USP Atenolol Related Compound A RS, USP Atenolol Related Compound B RS, USP Atenolol Related Compound E RS, and USP Atenolol Related Compound F RS from the corresponding Impurity stock solution in Mobile phase
Sample solution: 2 mg/mL of Atenolol in Mobile phase prepared as follows. Transfer a suitable amount of Atenolol to a suitable volumetric flask. Add Mobile phase to 50% of the final volume and sonicate to dissolve. Dilute with Mobile phase to volume.
Chromatographic system: Proceed as directed in the Assay, except for the Run time.
Run time: NLT 5 times the retention time of atenolol
System suitability
Samples: Sensitivity solution and Standard solution
[Note—See Table 1 for relative retention times.]
Suitability requirements
Resolution: NLT 2.0 between atenolol related compound B and atenolol related compound A, Standard solution
Relative standard deviation: NMT 2.0% for atenolol and NMT 5.0% each for atenolol related compounds A, B, E, and F, Standard solution
Signal-to-noise ratio: NLT 10, Sensitivity solution
Analysis
Samples: Standard solution and Sample solution
Calculate the percentage of atenolol related compounds A, B, E, and F in the portion of Atenolol taken:
Result = (rU / rS) × (CS / CU) × 100
rU = peak response of atenolol related compound A, B, E, or F from the Sample solution
rS = peak response of atenolol related compound A, B, E, or F from the Standard solution
CS = concentration of the corresponding Reference Standard in the Standard solution (mg/mL)
CU = concentration of Atenolol in the Sample solution (mg/mL)
Calculate the percentage of atenolol related compound G and any unspecified impurity in the portion of Atenolol taken:
Result = (rU / rS) × (CS / CU) × (1/F) × 100
rU = peak response of atenolol related compound G or any unspecified impurity from the Sample solution
rS = peak response of atenolol from the Standard solution
CS = concentration of USP Atenolol RS in the Standard solution (mg/mL)
CU = concentration of Atenolol in the Sample solution (mg/mL)
F = relative response factor for atenolol related compound G or any unspecified impurity (see Table 1)
Acceptance criteria: See Table 1. The reporting threshold is 0.025%.
| Name | Relative Retention Time | Relative Response Factor | Acceptance Criteria, NMT (%) |
| Atenolol related compound B | 0.31 | — | 0.15 |
| Atenolol related compound A | 0.41 | — | 0.15 |
| Atenolol | 1.0 | — | — |
| Atenolol related compound E | 1.72 | — | 0.15 |
| Atenolol related compound Fᵃ | 2.04 and 2.17 | — | 0.15 |
| Atenolol related compound Gᵇ | 3.58 | 0.84 | 0.15 |
| Any unspecified impurity | — | 1.00 | 0.10 |
| Total impurities | — | — | 0.50▲ (USP 1-May-2022) |
ᵃ For quantification purposes, integrate the doublet peaks of atenolol related compound F.
ᵇ 2-{4-[2-Hydroxy-3-(isopropylamino)propoxy]phenyl}acetic acid.
5 SPECIFIC TESTS
Delete the following:
Melting Range or Temperature, Class I〈741〉: 152°–156.5°▲ (USP 1-May-2022)
Loss on Drying 〈731〉
Analysis: Dry at 105° to constant weight.
Acceptance criteria: NMT 0.5%
6 ADDITIONAL REQUIREMENTS
Change to read:
Packaging and Storage: Preserve in well-closed containers. Store at controlled (USP 1-May-2022) room temperature.
Change to read:
USP Reference Standards 〈11〉
USP Atenolol RS
USP Atenolol Related Compound A RS
2-(4-Hydroxyphenyl)acetamide.
C₈H₉NO₂ 151.17
USP Atenolol Related Compound B RS
2-[4-(2,3-Dihydroxypropoxy)phenyl]acetamide.
C₁₁H₁₅NO₄ 225.24
USP Atenolol Related Compound E RS
2,2'-{[(2-Hydroxypropane-1,3-diyl)bis(oxy)]bis(4,1-phenylene)}diacetamide.
C₁₉H₂₂N₂O₅ 358.39
USP Atenolol Related Compound F RS
2,2'-[{[(Isopropylazanediyl)bis(2-hydroxypropane-3,1-diyl)]bis(oxy)}bis(4,1-phenylene)]diacetamide.
C₂₅H₃₅N₃O₆ 473.57▲ (USP 1-May-2022)