1 DEFINITION

Amcinonide Cream is Amcinonide in a suitable cream base. It contains NLT 90.0% and NMT 115.0% of the labeled amount of amcinonide (C28H35FO7).

2 IDENTIFICATION

Change to read:

A. The retention time of the amcinonide peak of the Sample solution corresponds to that of the Standard solution, as obtained in the Assay. (USP 1-Dec-2019)

3 ASSAY

Change to read:

3.1 Procedure

Solution A: Acetonitrile and water (35:65) (USP 1-Dec-2019)

Solution B: Acetonitrile and water (70:30) (USP 1-Dec-2019)

Mobile phase: See Table 1. Equilibrate the system with Solution A.

Table 1

Time (min)Solution A (%)Solution B (%)
01000
2.51000
100100
250100
261000
321000 (USP 1-Dec-2019)

System suitability solution: 12.5 μg/mL of USP Butylparaben RS (USP 1-Dec-2019) and 20 μg/mL of USP Amcinonide RS in Solution B

Standard solution: 0.02 mg/mL of USP Amcinonide RS in Solution B

Sample stock solution: Nominally 0.2 mg/mL of amcinonide from Cream prepared as follows. Transfer a quantity of Cream, equivalent to 10 mg of amcinonide, to a 50-mL volumetric flask. Add 5 mL of Solution B and 15 mL of acetonitrile, and heat over a steam bath until dissolved. Add 20 mL of Solution B while hot, cool to room temperature, dilute with Solution B to volume, and refrigerate for 30 min.

Vigorously shake the solution to disperse the mixture, and filter while cold. Use the filtrate.

Sample solution: Nominally 0.02 mg/mL of amcinonide from the Sample stock solution (USP 1-Dec-2019) in Solution B

3.2 Chromatographic system

Mode: LC

Detector: UV 254 nm

Column: 4.6-mm × 25-cm; 5-μm (USP 1-Dec-2019) packing L1

Flow rate: 2 mL/min

Injection volume: 10 μL

3.3 System suitability

Samples: System suitability solution and Standard solution

[Note - The relative retention times for butylparaben and amcinonide are 0.78 and 1.0, respectively.]

3.4 Suitability requirements

Resolution: NLT 8.0 between butylparaben and amcinonide, System suitability solution

Tailing factor: NMT 1.5, Standard solution

Relative standard deviation: NMT 2.0%, Standard solution

3.5 Analysis

Samples: Standard solution and Sample solution

Calculate the percentage of the labeled amount of amcinonide (C28H35FO7) in the portion of Cream taken:

Result = (ru/rs) × (Cs/Cu) × 100

r= peak response from the Sample solution

rs = peak response from the Standard solution

Cs = concentration of USP Amcinonide RS in the Standard solution (mg/mL)

Cu = nominal concentration of amcinonide in the Sample solution (mg/mL)

Acceptance criteria: 90.0%–115.0%

4 PERFORMANCE TESTS

Minimum Fill 〈755〉: Meets the requirements

5 SPECIFIC TESTS

Change to read:

Microbial Enumeration Tests 〈61〉 and Tests for Specified Microorganisms 〈62〉: The total aerobic microbial count is NMT 102cfu/g and the totalyeast and mold count is NMT 101cfu/g. (USP 1-Dec-2019) It meets the requirements of the tests for absence of Staphylococcus aureus and Pseudomonas aeruginosa.

pH 〈791〉: 3.5–5.2

6 ADDITIONAL REQUIREMENTS

Change to read:

Packaging and Storage: Preserve in tight containers.▲Store at controlled room temperature.▲ (USP 1-Dec-2019)

Change to read:

USP Reference Standards 〈11〉

USP Amcinonide RS

USP Butylparaben RS