0.1 N Titanium Trichloride VS

If you find any inaccurate information, please let us know by providing your feedback here

0.1 N Titanium Trichloride VS

Ước tính: 0 phút đọc, Ngày đăng:

Tóm tắt nội dung

  1. Standardization

This article is compiled based on the United States Pharmacopeia (USP) – 2025 Edition

Issued and maintained by the United States Pharmacopeial Convention (USP)

DOWNLOAD PDF HERE

(USP 1-Aug-2020)

Add 75 mL of titanium trichloride solution (1 in 5) to 75 mL of hydrochloric acid, dilute with water (USP 1-Aug-2020) to 1000 mL, and mix.

1 Standardization

See Volumetric Solutions, 1. Definitions.

See Titrimetry (541).

Standardize by one of the following procedures. [NOTE-Other standardization procedures may be used. See Volumetric Solutions, 2. Preparation and Standardization, 2.3 Standardization.] (USP 1-Aug-2020)

Apparatus: Store the titanium trichloride solution in the reservoir of a closed-system titration apparatus in an atmosphere of inert gas.

(USP 1-Aug-2020)

Use a wide-mouth, 500-mL conical flask as the titration vessel, and connect it by means of a tight-fitting rubber stopper to the titration buret, an inlet tube for inert gas. (USP 1-Aug-2020) and an exit tube. Arrange for mechanical stirring. All joints must be air-tight. Arrange to have

the inert gas (USP 1-Aug-2020) pass through a wash bottle containing titanium trichloride solution (approximately 1 in 50) to remove any oxygen.

If the solution to be titrated is to be heated before or during titration, connect the titration flask with an upright reflux condenser through the rubber stopper.

Standardization with visual endpoint: (USP 1-Aug-2020) Place an accurately measured volume of about 40 mL of 0.1 N ferric ammonium sulfate VS in the titration flask, and pass in a rapid stream of inert gas (USP 1-Aug-2020) until all the air has been removed. Add the titanium trichloride solution from the buret until near the calculated endpoint (about 35 mL), then add through the outlet tube 5 mL of ammonium thiocyanate TS, and continue the titration until the solution is colorless.

N= [mL FeNH4(SO4)2 × N FeNH4(SO4)2] / mL TiCl3

Standardization with potentiometric endpoint: Place an accurately measured volume of about 10 mL of 0.1 N ferric ammonium sulfate VS in the titration flask, and pass in a rapid stream of inert gas until all the air has been removed. Titrate with the titanium trichloride solution potentiometrically using a combined platinum electrode.

N= [mL FeNH4(SO4)2 × N FeNH4(SO4)2] / mL TiCl3

(USP 1-Aug-2020)

[NOTE-If this volumetric solution is used in a qualitative application such as pH adjustment, dissolution medium, or diluent, its standardization is not required.]

vui lòng chờ tin đang tải lên

Vui lòng đợi xử lý......

0 SẢN PHẨM
ĐANG MUA
hotline
0927.42.6789